Reòta-thiormaichte 11 seòrsa de phataigin analach searbhag niùclasach

Tuairisgeul Goirid:

Tha an inneal seo air a chleachdadh airson lorg càileachdail a dhèanamh air pathogens analach cumanta ann an sputum daonna, nam measg Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella pneumoniae (KPN), Stenotrophomonas maltophilia (Smet), Bordetella pertussis (Bp), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Leg). Faodar toraidhean an deuchainn a chleachdadh airson breithneachadh taiceil air euslaintich san ospadal no euslaintich a tha gu dona tinn le galar bacteriach fo amharas anns an t-slighe analach.


Mion-fhiosrachadh Toraidh

Tagaichean Bathar

Ainm an toraidh

HWTS-RT190 - Reòta-thiormaichte-Reòta-thiormaichte 11 Seòrsa de Pathogens Analach Pasgan Lorgaidh Aigéad Niùclasach (PCR Fluorescence)

Eipeidimeo-eòlas

Tha galar an t-slighe analach na ghalar cudromach a tha gu mòr a’ bagairt slàinte dhaoine. Tha sgrùdaidhean air sealltainn gu bheil a’ mhòr-chuid de ghalaran an t-slighe analach air adhbhrachadh le pathogens bacterial agus/no bhìorasach a bhios a’ co-ghalarachadh an aoigh, ag adhbhrachadh barrachd dona sa ghalar no eadhon bàs. Mar sin, faodaidh aithneachadh a’ phataigin làimhseachadh cuimsichte a thoirt seachad agus ìre mairsinn an euslaintich a leasachadh [1,2]. Ach, tha dòighean traidiseanta airson pathogens analach a lorg a’ toirt a-steach sgrùdadh microscopach, cultar bacterial, agus sgrùdadh imdhíoneolaíoch. Tha na dòighean sin iom-fhillte, a’ toirt ùine, gu teicnigeach dùbhlanach, agus tha cugallachd ìosal aca. A bharrachd air an sin, chan urrainn dhaibh iomadh pathogen a lorg ann an aon sampall, ga dhèanamh duilich breithneachadh taiceil ceart a thoirt do dhotairean. Mar thoradh air an sin, tha a’ mhòr-chuid de chungaidhean fhathast aig ìre cungaidh-leigheis empirigeach, a tha chan ann a-mhàin a’ luathachadh cearcall an aghaidh bacterial, ach cuideachd a’ toirt buaidh air breithneachadh ùineail euslaintich [3]. Tha Haemophilus influenzae cumanta, Acinetobacter baumannii, Pseudomonas aeruginosa, Klebsiella pneumoniae, Streptococcus pneumoniae, Stenotrophomonas maltophilia, Bordetella pertussis, Bordetella parapertussis, Mycoplasma pneumoniae, Chlamydia pneumoniae, agus Legionella pneumophila nan pathogens cudromach a dh’ adhbhraicheas galairean analach nosocomial [4,5]. Bidh an inneal deuchainn seo a’ lorg agus a’ comharrachadh searbhagan niuclasach sònraichte nam pathogens gu h-àrd ann an daoine le comharran agus comharraidhean galair analach, agus ga chur còmhla ri toraidhean obair-lann eile gus cuideachadh le bhith a’ lorg galair pathogen analach.

Paramadairean Teicnigeach

Stòradh

2-30℃

Beatha sgeilp 12 mìosan
Seòrsa Eisimpleir Suab amhaich
Ct ≤33
CV <5.0%
LoD Is e 500 CFU/mL LoD a’ phasgan airson Klebsiella pneumoniae; is e 500 CFU/mL LoD Streptococcus pneumoniae; is e 1000 CFU/mL LoD Haemophilus influenzae; is e 500 CFU/mL LoD Pseudomonas aeruginosa; is e 500 CFU/mL LoD Acinetobacter baumannii; is e 1000 CFU/mL LoD Stenotrophomonas maltophilia; is e 500 CFU/mL LoD Bordetella pertussis; is e 500 CFU/mL LoD Bordetella parapertussis; is e 200 leth-bhreac/mL LoD Mycoplasma pneumoniae; is e 1000 CFU/mL LoD Legionella pneumophila; Is e 200 leth-bhreac/mL an LoD airson Chlamydia pneumoniae.
Sònrachas Chan eil crois-bhualadh eadar an inneal agus pathogens analach cumanta eile taobh a-muigh raon lorg an inneil deuchainn, me Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Serratia marcescens, Enterococcus faecalis, Candida albicans, Klebsiella oxytoca, Streptococcus pyogenes, Micrococcus luteus, Rhodococcus equi, Listeria monocytogenes, Acinetobacter junii, Haemophilus parainfluenzae, Legionella dumov, Enterobacter aerogenes, Haemophilus haemolyticus, Streptococcus salivarius, Neisseria meningitidis, Mycobacterium tuberculosis, bhìoras Influenza A, bhìoras Influenza B, Aspergillus flavus, Aspergillus terreus, Aspergillus fumigatus, Candida glabrata, agus Candida tropicalis.
Ionnsramaidean Iomchaidh

Seòrsa I: Siostaman PCR Fìor-Ùine Applied Biosystems 7500, Siostaman PCR Fìor-Ùine Luath Applied Biosystems 7500, QuantStudio®5 Siostaman PCR Fìor-Ùine, Siostaman PCR Fìor-Ùine SLAN-96P (Hongshi Medical Technology Co., Ltd.), LightCycler®480 Siostam PCR Fìor-Ùine, Siostaman Lorgaidh PCR Fìor-Ùine LineGene 9600 Plus (FQD-96A, teicneòlas Hangzhou Bioer), Cearcall Teirmeach Meudach Fìor-Ùine MA-6000 (Suzhou Molarray Co., Ltd.), Siostam PCR Fìor-Ùine BioRad CFX96, Siostam PCR Fìor-Ùine BioRad CFX Opus 96.

Seòrsa II: EudemonTMAIO800 (HWTS-EQ007) le Jiangsu Macro & Micro-Test Med-Tech Co. Ltd.

Sruth-obrach

Seòrsa I: Thathar a’ moladh Pasgan DNA/RNA Bhìorasach Macro & Micro-Test (HWTS-3017) (a ghabhas cleachdadh le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) le Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. airson an sampall a thoirt a-mach agus bu chòir na ceumannan às dèidh sin a dhèanamh a rèir IFU a’ Phasgan.


  • Roimhe: