12 Seòrsa de Pathogen Analach
Ainm an toraidh
HWTS-RT071A 12 Seòrsa de Inneal Lorgaidh Aigéad Niùclasach Pathogen Analach (PCR Fluorescence)
Sianal
Sianal | hu12Bufair Ath-bhualadh A | hu12Bufair Ath-bhualadh B | hu12Bufair Ath-bhualadh C | hu12Bufair Ath-bhualadh D |
FAM | SARS-CoV-2 | HADV | HPIV Ⅰ | HRV |
VIC/HEX | Smachd In-ghabhail | Smachd In-ghabhail | HPIV II | Smachd In-ghabhail |
CY5 | IFV A | MP | HPIV Ⅲ | / |
ROX | IFV B | RSV | HPIV Ⅳ | HMPV |
Paramadairean Teicnigeach
Stòradh | ≤-18℃ |
Beatha sgeilp | 12 mìosan |
Seòrsa Eisimpleir | Suab oropharyngeal |
Ct | ≤38 |
CV | ≤5.0% |
LoD | SARS-CoV-2:300 leth-bhreac/mLbhìoras cnatan-mòr B: 500 leth-bhreac/mlbhìoras flù A: 500 leth-bhreac/ml Adenovirus: 500 leth-bhreac/ml mycoplasma pneumoniae:500 leth-bhreac/ml bhìoras syncytial analach: 500 leth-bhreacan / mL, bhìoras parainfluenza (Ⅰ, Ⅱ, Ⅲ, Ⅳ): 500 leth-bhreac/mL Rhinovirus: 500 leth-bhreac/ml metapneumovirus daonna: 500 leth-bhreac/mL |
Sònrachas | Tha an sgrùdadh air ath-bhualadh crois a’ sealltainn nach eil ath-bhualadh crois eadar an inneal seo agus enterovirus A, B, C, D, bhìoras Epstein-barr, bhìoras a’ bhreac, cytomegalovirus daonna, rotavirus, norovirus, bhìoras a’ ghriùthaich, bhìoras varicella-herpes zoster, bordetella pertussis, streptococcus pyogenes, mycobacterium tuberculosis, aspergillus fumigatus, candida albicans, candida glabrata, pneumocystis jirovecii, cryptococcus neoformans agus searbhag niuclasach genomic daonna. |
Ionnsramaidean Iomchaidh | Siostaman PCR Fìor-Ùine Applied Biosystems 7500Siostaman PCR Fìor-Ùine Luath Applied Biosystems 7500QuantStudio®5 Siostaman PCR Fìor-Ùine Siostaman PCR Fìor-Ùine SLAN-96P (Hongshi Medical Technology Co., Ltd.) Rothadair-solais®Siostam PCR fìor-ùine 480, Siostam Lorgaidh PCR Fìor-Ùine LineGene 9600 Plus (FQD-96A, teicneòlas Hangzhou Bioer) Cearcall-chuairteachaidh teirmeach cainneachdail fìor-ùine MA-6000 (Suzhou Molarray Co., Ltd.) Siostam PCR Fìor-ùine BioRad CFX96 Siostam PCR Fìor-Ùine BioRad CFX Opus 96 |
Sruth-obrach
Roghainn 1.
Reagent às-tharraing a thathar a’ moladh: Reagent Sgaoilidh Sampall Macro & Micro-Test (HWTS-3005-8) le Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Bu chòir an tarraing a dhèanamh gu teann a rèir an stiùiridh.
Roghainn 2.
Reagent às-tharraing a thathar a’ moladh: Pasgan DNA/RNA Coitcheann Macro & Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) agus Inneal-tarraing searbhag niuclasach fèin-ghluasadach Macro & Micro-Test (HWTS-3006C, HWTS-3006B) le Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., bu chòir an às-tharraing a dhèanamh a rèir an stiùiridh gu teann. Is e 80μL an tomhas-lìonaidh elution a thathar a’ moladh.
Roghainn 3.
Reactant às-tharraing a thathar a’ moladh: Pasgan Às-tharraing no Glanaidh aigéad niùclasach (YDP315) le Tiangen Biotech (Beijing) Co., Ltd., bu chòir an às-tharraing a dhèanamh a rèir an stiùiridh gu teann. Is e 100μL an tomhas-lìonaidh elution a thathar a’ moladh.