11 Seòrsa de Pathogen Analach

Tuairisgeul Goirid:

Tha an inneal seo air a chleachdadh airson lorg càileachdail in vitro air pathogens analach clionaigeach cumanta ann an sputum daonna, nam measg Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN), Stenotrophomonas maltophilia (Smet), Bordetella pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Leg). Faodar na toraidhean a chleachdadh mar chuideachadh ann a bhith a’ lorg euslaintich san ospadal no a tha gu dona tinn le galairean bacteriach fo amharas anns an t-slighe analach.Tha an inneal seo air a chleachdadh airson lorg càileachdail in vitro air pathogens analach clionaigeach cumanta ann an sputum daonna, nam measg Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN), Stenotrophomonas maltophilia (Smet), Bordetella pertussis (BP), Bacillus parapertusss (Bpp), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (Cpn), Legionella pneumophila (Leg). Faodar na toraidhean a chleachdadh mar chuideachadh ann a bhith a’ lorg euslaintich san ospadal no a tha gu dona tinn le galairean bacteriach fo amharas anns an t-slighe analach.


Mion-fhiosrachadh Toraidh

Tagaichean Bathar

Ainm an toraidh

HWTS-RT162A 11 Seòrsa de Inneal Lorgaidh Aigéad Niùclasach airson Pathogenan Analach(PCR Fluaraiseachd)

Sianal

靶标 Sianal
核酸反应液A 核酸反应液B 核酸反应液C 核酸反应液D
HI Smet MP Cos FAM
SP PA Bp / CY5
KPN ABA Bpp Cpn ROX
内参 内参 内参 内参 VIC/HEX

Eipeidimeo-eòlas

Tha galairean an t-slighe analach nan clas cudromach de ghalaran a tha nan cunnart mòr do shlàinte dhaoine, agus tha sgrùdaidhean air sealltainn gu bheil a’ mhòr-chuid de ghalaran an t-slighe analach air adhbhrachadh le pathogens bacteriach agus/no bhìorasach a bhios a’ co-ghalarachadh an aoigh, ag adhbhrachadh barrachd dona sa ghalair agus eadhon bàs, agus mar sin le bhith a’ soilleireachadh a’ phataigin leigidh sin le làimhseachadh cuimsichte agus a’ leasachadh ìre mairsinn an euslaintich.[1,2].

Paramadairean Teicnigeach

Stòradh

≤-18℃

Beatha sgeilp 12 mìosan
Seòrsa Eisimpleir Sputum
Ct HI, SP, KPN, PA, ABA, Smet: Ct≤33BP, Bpp, MP, Cpn, Cas: Ct≤38
CV <5.0%
LoD Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonasaeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia agus Legionellaniùmophila: 1000 CFU/mL

Bordetella pertussis agus Bacillus parapertussis: 500 CFU/mL;

Mycoplasma pneumoniae agus Chlamydia pneumoniae: 200 leth-bhreac/mL.

Sònrachas Sheall toraidhean an deuchainn ath-ghnìomhachd-tharsainn nach robh ath-bhualadh-tharsainn eadar an inneal seo agus Cytomegalovirus, bhìoras Herpes simplex seòrsa 1, bhìoras Varicella-zoster, bhìoras Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillus, Legionella pneumophila, Moraxella catarrhalis, sreathan lagaichte de Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella pneumoniae, Chlamydia psittaci, Coxiella burnetii agus aigéid niuclasach genomic daonna.
Ionnsramaidean Iomchaidh Siostaman PCR Fìor-Ùine Applied Biosystems 7500

Siostaman PCR Fìor-Ùine Luath Applied Biosystems 7500

QuantStudio®5 Siostaman PCR Fìor-Ùine

Siostaman PCR Fìor-Ùine SLAN-96P

Rothadair-solais®Siostam PCR fìor-ùine 480

Siostaman Lorgaidh PCR Fìor-Ùine LineGene 9600 Plus

Cearcall-chuairteachaidh teirmeach cainneachdail fìor-ùine MA-6000

Siostam PCR Fìor-ùine BioRad CFX96

Siostam PCR Fìor-Ùine BioRad CFX Opus 96

Sruth-obrach

Pasgan DNA/RNA Coitcheann Macro & Micro-Test (HWTS-3019) (a ghabhas cleachdadh le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) le Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Cuir 200µL defiseòlasachsaline ris an deascadh a chaidh a phròiseasadh, agus bu chòir na ceumannan às dèidh sin a dhèanamh a rèir an stiùiridh. Is e 100 µL an tomhas-lìonaidh elution a thathar a’ moladh.


  • Roimhe:
  • Air adhart:

  • Sgrìobh do theachdaireachd an seo agus cuir thugainn i